Straight Vegetable Oil System
Custom-Made Components for Diesel/Hybrid Vehicles
|
| Valve $45.00 + shipping |
 |
| NEW!!
FILTRATION SYSTEM $1,950.00 +
Shipping |
|

MODEL JL- 50 |
Filter your used vegetable oil to 5 microns up to 3,000 liters per hour under the proper conditions according to the manufacture. Fully cleanable and reusable filters.
II Flow chart and structures
It is of three-stage filtration, small and flexible size, easy to operate and maintain .requires no filter paper and causes no contamination to the ground, It can not only purify off the harmful impurities, but also can be used to fill and take out oil for oil equipment.
III Technical Data and Quality indexes
| Model |
Flow rate (KL/h) |
Lift (m) |
Cleanliness
(NSA) |
Power of
Motor(KW) |
Power |
Net weight (Kg) |
| JL-32 |
1.9 |
5 |
7 |
0.75 |
3 Phase 50Hz 380v 1 phase 120
or 240 volt 60 Hz available |
95 |
| JL-50 |
3 |
8 |
6 |
0.75 |
|
105 |
| JL-80 |
4.8 |
8 |
6 |
2.2 |
|
120 |
| JL-100 |
6 |
10 |
6 |
3 |
|
130 |
| JL-150 |
9 |
12 |
6 |
4 |
|
135 |
| JL-200 |
12 |
15 |
5 |
5 |
|
140 |
| JL-300 |
18 |
15 |
5 |
6 |
|
145 |
|
*** the JL 50 is capable of up to 3000 liters per hour under the proper conditions.
Ⅳ Operating instructions
A. To place the machine on the level ground or trailer and check carefully the parts are tight or not. Especially notice if the motor connect with oil pump tightly
B. To connect the power line correctly. Start-up the oil pump and to check the rotating direction is right or not. otherwise change the power place.
C. To connect and tighten the oil inlet pipe. Note, It’s very important to tighten the oil inlet and outlet pipe. otherwise ,It leads to falling off of the pipe with the increase of the
pressure.D. To start the motor button after tightened the oil inlet pipe. the oil pump begin to run. then the oil become purified oil after three-stage filtration.
E. When one barrel of oil be finished and need to change other one. The whole exchange process should be finished quickly. If the time is limited, you can stop the machine till connect the oil inlet pipe, then restart
Ⅴ Maintenance and Troubleshooting
A. It mainly adopts mechanical filtration. and decrease the density of filter step by step to improve the precision of filtration. so, the primary filter is easy to be jammed, it leads to the oil inlet capacity lower than oil out.
Method to solve: Remove the cover of primary filter. Then take out the filter, The machine can be work after clean it with the clean oil of same model
B. If the lift is too high during the process of filling oil, it will lead to increase temperature of motor and noise of oil pump.
Method to solve:1.To work as setting lift.2 discontinuous work
C. The noise of oil pump increase
Method to solve: 1.To check the oil pump axis are connected.2 To check the screws are tight or not.
D. Prohibit lack of phase. To avoid the motor be burned.
CLICK